Temperature dependent timer
- 4 timers runs for a couple of seconds, each time a time period corresponding to the specified number of minutes has elapsed
- Cycle time can be set in cycles of 2, 5, 10, 20, 30, 60, 120, 180, 240, 300, 360 or 480 minutes, individually for each hour
- Driving time varies with the temperature from min. to max. number of seconds specified. Temperature - The band is set with high and low value
- The 4 timers divids time (do not drive at the same time as water pressure will be too low). I.e. max 25% to each. However, it is possible to drive more, but then it will be with the others. Factory setting: At 30 ° C run 30 seconds every 10 minutes
- Constant function for driving all the time, or you can set to run a fixed number of seconds for each cycle
- Alarm limits for high and low temperature, cable break and short-circuit input
- Data collection of temperature
- Active / Discontinued period. You can set 2 times between which the function is active. Outside the specified times, the nozzles do not run - for example at night. Individual for each hour
- Communication with Dr.Bell TALECOMPUTER / alarm system. Can be operated by phone